Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
2.
Tropical Biomedicine ; : 283-288, 2021.
Article in English | WPRIM | ID: wpr-904807

ABSTRACT

@#Various methods have been developed for rapid and high throughput full genome sequencing of SARS-CoV-2. Here, we described a protocol for targeted multiplex full genome sequencing of SARS-CoV-2 genomic RNA directly extracted from human nasopharyngeal swabs using the Ion Personal Genome Machine (PGM). This protocol involves concomitant amplification of 237 gene fragments encompassing the SARS-CoV-2 genome to increase the abundance and yield of viral specific sequencing reads. Five complete and one near-complete genome sequences of SARS-CoV-2 were generated with a single Ion PGM sequencing run. The sequence coverage analysis revealed two amplicons (positions 13 751-13 965 and 23 941-24 106), which consistently gave low sequencing read coverage in all isolates except 4Apr20-64Hu. We analyzed the potential primer binding sites within these low covered regions and noted that the 4Apr20-64-Hu possess C at positions 13 730 and 23 929, whereas the other isolates possess T at these positions. The genome nucleotide variations observed suggest that the naturally occurring variations present in the actively circulating SARS-CoV-2 strains affected the performance of the target enrichment panel of the Ion AmpliSeq™ SARS CoV 2 Research Panel. The possible impact of other genome nucleotide variations warrants further investigation, and an improved version of the Ion AmpliSeq™ SARS CoV 2 Research Panel, hence, should be considered.

3.
Tropical Biomedicine ; : 613-621, 2021.
Article in English | WPRIM | ID: wpr-936385

ABSTRACT

@#The recommended test guidelines for Zika virus (ZIKV) include using both molecular and serological tools. While the molecular tools are useful for detecting acute infection, the serological tools are useful for the detection of previous infections. Nevertheless, detection of ZIKV-specific antibodies remains a challenge due to the high cross-reactivity between ZIKV and other flaviviruses such as dengue virus (DENV) and Japanese encephalitis virus (JEV). The objective of this study is to evaluate the commercially available enzyme-linked immunosorbent assay (ELISA) for the detection of ZIKV IgG. In this study, we evaluated 6 commercially available anti-ZIKV IgG ELISA kits. Pre-characterized serum panels consisting of 70 sera were selected for the evaluation. The diagnostic accuracy of each ELISA kits was determined and compared to the gold standard, Foci Reduction Neutralization Test (FRNT). The present study established that the performance of the NS1-based anti-ZIKV IgG ELISA kit was superior to that which uses of the E protein as antigen. Overall, commercial ZIKV IgG ELISA showed varying test performances, with some achieving moderate to high test sensitivities and specificities. When compared against the FRNT, the test sensitivities ranged from 7.1% to 78.6%, whereas, the test specificities ranged from 40.0% to 100%. Limitation to the study includes the cross reactivity between flavivirus and specificity of the kit in addressing the cross reactivity.

SELECTION OF CITATIONS
SEARCH DETAIL